CytScop® Pro automatic intelligent cell analyzer uses trypan blue staining exclusion method and AOPI double fluorescent staining method to determine the cell viability. It is equipped with bright field and fluorescent large-field microscopic optical systems and disposable microfluidic consumables. The system is designed with high-precision cell recognition algorithms, combined with a fully automatic and high-throughput operating mode, it can achieve accurate, stable, efficient, economical and standard process analysis of cell counts and viability in the field of biopharmaceuticals.

 

Product features

                                             

CytScop®Pro Automatic Intelligent Cell Analyzer


Ÿ   Fully automatic: dispensing samples, loading consumables, dyeing, photographing, analyzing and cleaning;

Ÿ   Microfluidic consumables: innovation, precision and high efficiency;

Ÿ   Intelligent algorithm: adapt to various cell types, accurate and anti-interference;

Ÿ   High throughput: 24-sample trays, single sample detection time <2 min, continuous measurement;

Ÿ   Dual fluorescence imaging system: wide field of view, high contrast;

Ÿ   Multiple dyeing modes meet different application requirements;

Ÿ   Compliant with 21CFR Part 11 requirements;

Ÿ   Comply with ALCOA+ principles for data integrity;

Ÿ   IQ/OQ verification procedures meeting GMP requirements.

 

CytScop®Pro Automatic Intelligent Cell Analyzer

 

Data Integrity and Compliance

CytScop® Pro automatic intelligent cell analyzer software is designed to monitor the cell counting & viability of cell culture process for biopharmaceutical applications, which is in compliance with the requirements of the US Food and Drug Administration (FDA) on electronic records and electronic signatures (21 CFR Part 11) and data integrity guidelines (ALCOA+), and also compliance with Good Practice (GxP) regulations for the entire process of analytical instrument qualification. By enabling the security options in the software, the system will automatically authorize users to adjust the following configurations to achieve compliance.


Ÿ   Audit trial

Ÿ   User authorization management

Ÿ   Log file

Ÿ   IQ/OQ validation

Ÿ   Electronic signature function

Ÿ   Instrument quality control

Ÿ   User security login

Ÿ   Standard beads

 

CytScop®Pro Automatic Intelligent Cell Analyzer

Flexible, innovative, and easy-to-use

Ÿ   Easy-to-install consumable package

Ÿ   Convenient data export

Ÿ   Various data formats

 

Meet clean room requirements

Ÿ   No external PC or monitor required

Ÿ   Smooth and easy-to-clean surface, without dead ends

Ÿ   Resistant to VHP

 

Stable and reliable data

Ÿ   High repeatability≤5%

Ÿ   High accuracy ±6%, R2>0.99

Ÿ   Data consistency CV≤7%

Ÿ   When the density is 2x106 cells/mL and above, the difference in the average sample density results between instruments will not exceed 10%, with a confidence level of 95%.

 

Case study

CytScop®Pro Automatic Intelligent Cell Analyzer

Data analysis

Item

Specification

Result

Ability to optimize analysis parameters

Yes

Improve accuracy and ensure method consistency

Density range

5 x 104 - 1.5 x 107 cells/mL

Reduce sample dilution

Counting accuracy

≤5% error compared to coulter   counter test @ ≥2 x 106 cells/mL

Accurate and reliable results

Count repeatability

Sample repeatability CV≤±5% @ ≥2 x 106 cells/mL

Stable and reliable results

Diameter range

5-60 μm

Meet testing needs of samples of different sizes

Roundness measurement

Yes

Helps identify debris in samples

 

Performance parameters

Features

Specification

Result

Autosampler

24-position autosampler cycle loading, fully automatic sample preparation

Walkaway during runtime

Allow to select counting mode

Trypan blue staining mode and AOPI staining mode

Meet different sample counting accuracy requirements

Dye pre-embedded consumables

Yes

No additional reagents or buffers required

Comply with 21CFR part 11   requirements

Yes

Meet GMP requirements

Sample volume

200 μL

Meet testing needs of small-scale cell culture

Analysis duration

2 min

Save time, increase throughput

Sample mixing times

Adjustable

Optimize depending on cell type, ensures accuracy of the results

Default cell analysis parameters

Yes

Easy to use with standard methods


Technical parameters

Item

Parameter

Optical sensor

630w CMOS Array

Brightfield channel

Yes

Fluorescence channel

EM1: 535 nm; EM2: 595 nm

Operating system

Win10 64-bit

Power requirements

110-230V/AC50/60Hz

Screen

12.1 inch

Hard drive capacity

500G

Working temperature

10-40

Working humidity

20-80

Weight

22 kg

Dimension

L x D x H: 54 x 38 x 43 cm

Ordering information of system

Part name

Model

Automatic Intelligent Cell Analyzer (dual fluorescence)

CA01

Automatic Intelligent Cell Analyzer (bright field)

CA02

 

Ordering Information of accessories and consumables

Part name

Model

TB microfluidic chip

MC01

AOPI microfluidic chip

MC02

System calibration chip

MC03

Starter kit

TK01

2M density control 2e6 cells/ml

MB01

4M density control 4e6 cells/ml

MB02

10M density control 10e6 cells/ml

MB03

* The above products are for industrial and scientific research only, not for diagnosis.




Contact Us
  • Tel.: +86 021 6434 0155
  • E-Mail: marketing@duoningbio.com
  • Address: Building 30, No. 1525 Minqiang Road, Songjiang District, Shanghai
Message

Copyright © Shanghai Duoning Biotechnology Co., Ltd. All Rights Reserved Sitemap | Technical Support: Reanod

WeChat
WeChat

Message-

Duoning Biotechnology

+86 021 6434 0155